66
Parameter list
3.1 Parameter list
The inverter is factory-set to display only the simple mode parameters.
Set Pr. 160 "extended function selection" as required.
Parameter Name
Factory
Setting
Setting
Range
Remarks
160
Extended function
selection
0
0 Accessible to only the simple mode parameters.
1 Accessible to all parameters.
CAUTION
• The blacked out parameters in the table below indicate simple mode parameters.
• The shaded parameters in the table allow its setting to be changed during operation even if "0" (factory
setting) is set in Pr. 77 (parameter write disable selection).
• *: Accessible when Pr. 77 = 801.
Function
Parameter
No.
Name Setting Range
Minimum
Setting
Increments
Factory Setting
Refer
To
Custo
mer
Setting
Basic functions
0 Torque boost (manual)
0 to 30% 0.1%
4%/3%/2%
(3.7K or less/
5.5K, 7.5K/
11K or more)
76
1 Maximum speed
0 to 3600r/min 1r/min 1500r/min 76
2 Minimum speed
0 to 3600r/min 1r/min 0r/min 76
3 Base frequency
10 to 200Hz 0.01Hz 60Hz 77
4 Multi-speed setting (high speed)
0 to 3600r/min 1r/min 1500r/min 77
5 Multi-speed setting (middle speed)
0 to 3600r/min 1r/min 750r/min 77
6 Multi-speed setting (low speed)
0 to 3600r/min 1r/min 150r/min 77
7 Acceleration time
0 to 3600s/0 to
360s
0.1s/0.01s
5s/15s
(1.5K to 5.5K
/7.5K to 55K)
78
8 Deceleration time
0 to 3600s/0 to
360s
0.1s/0.01s
5s/15s
(1.5K to 5.5K
/7.5K to 55K)
78
9 Electronic thermal O/L relay
0 to 500A 0.01A 0A 80
Standard
operation
functions
10 DC injection brake operation speed
0 to 1500r/min,
9999
0.1r/min 15r/min 82
11 DC injection brake operation time
0 to 0.5s 0.1s 0.5s 82
12 DC injection brake voltage
0 to 30% 0.1%
4%/2%
(7.5K or less/
11K or more)
82
13 Starting speed
0 to 1500r/min 0.1r/min 15r/min 84
15 Jog speed setting
0 to 1500r/min 0.1r/min 150r/min 85
16 Jog acceleration/deceleration time
0 to 3600s/0 to
360s
0.1s/0.01s 0.5s 85
Operation
selection
functions
17 MRS input selection
0, 2 1 0 86
19 Base frequency voltage
0 to 1000V, 8888,
9999
0.1V 9999 77
20
Acceleration/deceleration reference
speed
1 to 3600r/min 1r/min 1500r/min 78
21 Acceleration/deceleration time increments
0, 1 1 0 78
22 Torque limit level
0 to 400% 0.1% 150% 87
24 Multi-speed setting (speed 4)
0 to 3600r/min,
9999
1r/min 9999 77
25 Multi-speed setting (speed 5)
0 to 3600r/min,
9999
1r/min 9999 77
26 Multi-speed setting (speed 6)
0 to 3600r/min,
9999
1r/min 9999 77
27 Multi-speed setting (speed 7)
0 to 3600r/min,
9999
1r/min 9999 77
28 Multi-speed input compensation
0, 1 1 0 88
29 Acceleration/deceleration pattern
0, 1, 2, 3, 4 1 0 89
30 Regenerative function selection
0, 1, 2 1 0 92
31 Speed jump 1A
0 to 3600r/min,
9999
1r/min 9999 93
32 Speed jump 1B
0 to 3600r/min,
9999
1r/min 9999 93