Mitsubishi Electronics FR-V520-1.5K to 55K Marine Battery User Manual


 
74
At-a-glance guide to functions
Application functions
Brake sequence Pr. 60, Pr. 278 to Pr. 285 {
××
Torque bias
Pr. 180 to Pr. 183, Pr. 187, Pr. 840
to Pr. 848, Pr. 904, Pr. 905
X42, X43
{
××
Regenerative function selection Pr. 30, Pr. 70 {{{
Soft-PWM Pr. 240 {{{
Torque characteristic selection Pr. 801 {{{
Encoder rotation direction Pr. 852 {{{
Number of encoder pulses Pr. 851 {{{
Conditional position control by contact input Pr. 465 to Pr. 494
××
{
Direct display and direct setting of motor constants Pr. 71, Pr. 82, Pr. 90 to Pr. 94, Pr. 859 {{{
Speed setting/display unit switchover
Pr. 37, Pr. 144, Pr. 81, Pr. 454, Pr. 505,
Pr. 811
{{{
Electronic gear Pr. 420, Pr. 421, Pr.505, Pr.811
××
{
Input functions
Multi-function input terminal assignment Pr. 180 to Pr. 183, Pr. 187 {{{
Analog input assignment/calibration Pr. 868 / Pr. 902 to Pr. 920
Terminals 1, 2, 3
{{{
Analog command filter time constant Pr. 822, Pr. 826, Pr. 832, Pr. 836 {{{
Override, polarity reversible Pr. 73, Pr. 252, Pr. 253 {{
×
Output stop Pr. 17, Pr. 180 to Pr. 183, Pr. 187 MRS {{{
Output functions
Multi-function output terminal assignment Pr. 190 to Pr. 192, Pr. 195 {{{
Speed limit output Pr. 190 to Pr. 192, Pr. 195 SL
×
{
×
Inverter running signal Pr. 13, Pr.190 to Pr. 192, Pr. 195 RUN {{{
Up-to-speed signal Pr. 41, Pr. 190 to Pr. 192, Pr. 195 SU {
××
Overload alarm signal Pr. 190 to Pr. 192, Pr. 195 OL
Speed detection signal
Pr. 42, Pr. 43, Pr. 50, Pr. 116,
Pr. 190 to Pr. 192, Pr. 195
FU, FU2, FU3
{
××
FB, FB2, FB3 {{{
Regenerative brake prealarm signal Pr. 190 to Pr. 192, Pr. 195 RBP {{{
Electronic thermal relay function prealarm signal Pr. 190 to Pr. 192, Pr. 195 THP {{{
PU operation mode signal Pr. 190 to Pr. 192, Pr. 195 PU {{{
Operation ready signal Pr. 190 to Pr. 192, Pr. 195 RY {{{
Output current detection signal, zero current detection
signal
Pr. 150, Pr. 151, Pr. 152, Pr. 153,
Pr. 190 to Pr. 192, Pr. 195
Y12, Y13
{{{
Fan fault output signal Pr. 190 to Pr. 192, Pr. 195 FAN {{{
Fin overheat prealarm signal Pr. 190 to Pr. 192, Pr. 195 FIN {{{
Forward, reverse rotation output signal Pr. 190 to Pr. 192, Pr. 195 Y30, Y31 {{{
Regenerative status output signal Pr. 190 to Pr. 192, Pr. 195 Y32 {{{
Operation ready 2 signal Pr. 190 to Pr. 192, Pr. 195 RY2 {{{
Low speed detection signal Pr. 190 to Pr. 192, Pr. 195, Pr. 865 LS {{{
Torque detection signal Pr. 190 to Pr. 192, Pr. 195, Pr. 864 TU {{{
Maintenance output
Pr. 190 to Pr. 192, Pr. 195,
Pr. 890 to Pr. 892
MT
{{{
Remote output
Pr. 190 to Pr.192, Pr. 195,
Pr. 495 to Pr. 497
REM
{{{
Instantaneous power failure (undervoltage) signal Pr. 190 to Pr. 192, Pr. 195 IPF {{{
Fault definition Pr. 190 to Pr. 192, Pr. 195, Pr. 875 ER {{
×
Minor fault output signal Pr. 190 to Pr. 192, Pr. 195 LF {{{
Alarm output signal Pr. 190 to Pr. 192, Pr. 195 ABC {{{
Monitor functions
DU/PU display data selection Pr. 52, Pr. 53 {{{
DA1, DA2 output/calibration
Pr. 54 to Pr. 56, Pr. 866, Pr. 158,
Pr. 900, Pr. 901
DA1, DA2
{{{
DA1 output filter Pr. 867 DA1 {{{
Running speed monitor Pr. 52 to Pr. 55, Pr.158 {{{
Output current monitor/output current peak value
monitor
Pr. 52 to Pr. 54, Pr. 56, Pr. 158
{{{
Output voltage monitor Pr. 52 to Pr. 54, Pr. 158 {{{
Preset speed monitor Pr. 52 to Pr. 55, Pr. 158 {{{
Output frequency monitor Pr. 52 to Pr. 55, Pr. 158 {{{
Motor torque monitor Pr. 52 to Pr. 54, Pr. 158, Pr. 866 {{{
Converter output voltage monitor, converter output
voltage peak value monitor
Pr. 52 to Pr. 54, Pr. 158
{{{
Category
Vector with encoder
Speed Torque Position
SF-V5RU
"Motor with encoder (standard,
constant torque)"
*: This function can be usable under
position control by parameter
setting.
Pr. number Terminal
Control
Applicable
Motor
Function