ELECTRICAL SYSTEM 14-25
Battery
NOTE
○
Increase the charging voltage to a maximum voltage of
25 V if the battery will not accept current initially. Charge
for no more than five minutes at the increased voltage
then check if the battery is drawing current.
○
If the battery will accept current, decrease the voltage
and charge by the standard charging method described
on the battery case. If the battery will not accept current
after 5 minutes, replace the battery.
Battery [A]
Battery Charger [B]
Standard Value [C]
•
Determine battery condition after refreshing charge.
○
Determine the condition of the battery 30 minutes after
completion of the charge by measuring the terminal volt-
age according to the table below.
Criteria Judgement
12.6 V or more Good
12.0 ∼ less than 12.6 V Charge insufficient → Recharge
less than 12.0 V Unserviceable → Replace