14-62 ELECTRICAL SYSTEM
Multifunction Meter
Buzzer Inspection
•
Make sure that the buzzer sounds correctly when turning
the ignition switch key to the “ON” position and warning
the trouble after connecting the buzzer between [9] and
[10].
•
If the output voltage between [9] and [10] is out of the
range during the buzzer sound, replace the meter assy.
Output Voltage
7 ∼ 14 V for normal sound, 2 ∼ 4 V for low sound.
Hand tester [A]
Multifunction Meter Circuit
1. Joint Connector Q
2. Fuel Level Sensor