Garmin G1000H Marine Radio User Manual


 
Garmin G1000H
Pilot’s Guide for the Bell 407GX
190-01255-00 Rev B60
FLIGHT INSTRUMENTS
Whenabearingpointerisdisplayed, itsassociatedinformationwindow isalsodisplayed. TheBearing
Informationwindows(Figure2-22)aredisplayedtothelowersidesoftheHSIanddisplaythefollowing
information:
•Bearingsource(NAV,GPS,ADF)
• Pointericon(BRG1=singleline,BRG2=doubleline)
•Frequency(NAV,ADF)
•Station/waypointidentier(NAV,GPS)
•GPS-derived great circle distance to bearing
source
WhentheNAVradioistunedtoanILSfrequencythebearingsourceandthebearingpointerisremoved
fromtheHSI.WhenNAV1orNAV2istheselectedbearingsource,thefrequencyisreplacedbythestation
identierwhenthestationiswithinrange.IfGPS isthe bearingsource,theactivewaypointidentier is
displayedinlieuofafrequency.
ThebearingpointerisremovedfromtheHSIand“NODATA”isdisplayedintheinformationwindowif
theNAVradioisnotreceivingthetunedVORstationorifGPSisthebearingsourceandanactivewaypoint
is not selected.
Selecting bearing display and changing sources:
1) Select the PFD Softkey.
2) Select a BRG Softkey to display the desired bearing pointer and information window with a NAV source.
3) Select the BRG Softkey again to change the bearing source to GPS.
4) To remove the bearing pointer and information window, select the BRG Softkey again.
DME INFORMATION WINDOW
The DMEInformationWindowisdisplayedabovetheBRG1InformationWindowonthe360˚HSIandin
aboxaboveandalongsidetheArcHSI.ItshowstheDMElabel,tuningmode(NAV1,NAV2,orHOLD),
frequency,anddistance.Whenasignalisinvalid,thedistanceisreplacedby–.––NMRefertotheAudio
PanelandCNSSectionforinformationontuningtheDME.
NOTE: DME installation is optional.
Displaying the DME Information Window:
1) Select the PFD Softkey.
2) Select the DME Softkey to display the DME Information Window.
3) To remove the DME Information Window, select the DME Softkey again.