GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743
Issue 1
November 2000
Translations and Testing
170Switch-to-INTUITY Translations
■ status link
X
, where
X
is the TCP/IP link number. In this example of
Page 1, the system shows that the link is connected and that the link is in
service.
Page 2 shows the error counts.
Page 3 shows whether the link is up or down. If the link is not up, there is a
problem somewhere in translations or connectivity.
■ status data-module
XXXX
, where
XXXX
is the extension number of the
ethernet data module. This shows which port is connected and if the port is
in service.
status link 1 Page 1 of 4
LINK/PORT STATUS
Link Number: 1
Link Status: connected
Link Type: ethernet
Link Name: ethernet data module
Service Port Location: 01B1017
Service Port Data Extension: 2000
Service Stats: in-service/active
Node Name: guestworks
Source IP Address: 192.168.1.10
Subnet Mask: 255.255.255.0
Broadcast Address: 192.168.1 .255
Physical Address: ff:ff:ff:ff:ff:ff
Enabled? yes
Maintenance Busy? no
Active Channels: 1
status link 1 Page 3 of 4
PROCESSOR CHANNEL STATUS
UP: 001
status data-module 3100
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 3100 Service State: in-service/active
Port/Channel Number: 01B1017 Maintenance Busy? no
CF Destination Ext:
Connected Ports: