GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743
Issue 1
November 2000
Translations and Testing
171Switch-to-INTUITY Translations
■ trace-route ip-address
address
board
CCs
, where
address
is the
INTUITY IP address, and
CCs
is the equipment location of the C-LAN
circuit pack. The command displays the hops traversed from source to
destination, along with the IP addresses of the hop points and final
destination, and the observed round-trip delay from the source to each hop
point. If no reply is received from a hop point, the IP address is blank.
■ list measurements clan ethernet
CCs
, where
CCs
is the cabinet, carrier,
and slot number of the C-LAN circuit pack. This command displays Cyclic
Redundancy Check and collision counts for the past 24 hours in 15-minute
intervals. N/A is displayed if the data cannot be retrieved for any interval.
trace-route ip-address 192.168.1.70 board 1b10
TRACE ROUTE RESULTS
Hop Time(ms) IP Address
0 Start Addr: 192.168.1.10
1 15, 15, 12 192.168.1.15
2 23, 26, 26 192.168.1.12
3 23, 25, 25 192.168.1.70
list measurements clan ethernet 1b10 Page 1 of 3
Switch Name: guestworks Date: 3:50 pm TUE AUG 17, 1999
C-LAN ETHERNET PERMORMANCE MEASUREMENT DETAILED REPORT
Date Time CRC CHECK Collision Count
total delta total delta
02/01 03:08 650 50 650 250
02/01 02:53 600 600 400 400
02/01 02:38 N/A N/A N/A N/A
02/01 02:23 1000000570 20 10000000570 20
02/01 02:08 1000000550 10000000550 10000000550 10000000550