Translations and Testing
175Switch-to-INTUITY Translations
The following table is an example of how you can administer the processor
interface channels (your extensions will differ). Only channel 01 will be enabled
later to handle the messaging traffic. The other channels are used for
maintenance and testing.
Data Module on an r System
Use the add data-module command on an
r
system to administer the data
module parameters for a packet gateway link. For this connection, the data
modules are integrated into the TN577 circuit pack. Set the options as shown,
except use the correct extension, COS, and COR as set up for your installation.
You must set the Enable Link field to n at this time. After you have set up the
processor interface channel, you must go back and enable the link.
Data
Extension
Physical
Channel
Maintenance
Extension
7991 01 7995
7992 02 7996
7993 03 7997
7994 04 7998
add data-module 2005 Page 1 of 2
DATA MODULE
Data Extension: 2005 Name: intuity link
Type: x.25 Remote Loop-Around Test? n
Port: 01C0301 COR: 50 Destination Number: external
Baud Rate: 9600 TN: 1 Establish Connection?
Endpoint Type: adjunct DTE/DCE: dte Connected Data Module:
Link: 1 Enable Link? n Error Logging? y
Permanent Virtual Circuit? y Highest PVC Logical Channel: 64
Switched Virtual Circuit? n