Translations and Testing
213Switch-to-PMS Link Translations
Data Modules
Use the add data-module command to administer the data module connected
between the switch and the PMS.
Housekeeping Status
Use the change feature-access-codes command to assign the housekeeping
status feature access codes. Administer only the feature access codes that the
vendor supports and that match the status definitions.
add data-module 7899
DATA MODULE
Data Extension: 7899 Name: PMS LINK BCC: 2
Type: pdm COS: 1 Remote Loop-Around Test? n
Port: 01B0102 COR: 50 Secondary data module? n
ITC: restricted TN: 1 Connected to: dte
ABBREVIATED DIALING
List1:
SPECIAL DIALING OPTION:
ASSIGNED MEMBER ( Station with a data extension button for this data module )
Ext Name
1:
change feature-access-codes Page 5 of 5
FEATURE ACCESS CODE (FAC)
Hospitality Features
Automatic Wakeup Call Access Code: *98
Housekeeping Status (Client Room) Access Code: *81
Housekeeping Status (Client Room) Access Code: *82
Housekeeping Status (Client Room) Access Code: *83
Housekeeping Status (Client Room) Access Code: *84
Housekeeping Status (Client Room) Access Code:
Housekeeping Status (Client Room) Access Code:
Housekeeping Status (Station) Access Code:
Housekeeping Status (Station) Access Code:
Housekeeping Status (Station) Access Code:
Housekeeping Status (Station) Access Code:
Verify Wakeup Announcement Access Code: *89
Voice Do Not Disturb Access Code: *33