Avaya 555-231-743 Life Jacket User Manual


 
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743
Issue 1
November 2000
Installing the System
77Connecting the Hospitality Adjuncts
INADS Alarm Origination Download
You can have the Comsphere 3820 or the RMB automatically configured by doing
an alarm origination download. To start this download, do the following:
1. Use the Customer/Services Administration > Alarm Management
command to display the following screen:
2. Enter the information as shown in the screen, using your actual Product
ID and Alarm Destination phone number (the INADS number).
3. Once the options are correct, press to save the options. Press
to continue.
4. Press to select the Chg Keys function.
5. Press to select the Test Alrm function.
6. Select the Execute Alarm Origination Test menu item.
7. Press y to start the test. The alarm origination download takes 2 to 5
minutes to complete.
8. After the download is complete, select the Review Latest Test Results
menu item. The result message should say Alarm origination test
successful.
For more details on this procedure, see the appropriate MAP installation
document.
+-----------------------------------------------+
+ Alarm Management +
+-----------------------------------------------+
|Product ID 2200000000 |
| |
|Alarm Destination 18005353573 |
| |
|Alarm Origination ACTIVE |
| |
|Alarm Level MAJOR |
| |
|Alarm Suppression INACTIVE |
| |
|Clear Alarm Notification ACTIVE |
+-----------------------------------------------+
F3 Enter
F8
F1