Avaya 555-231-743 Life Jacket User Manual


 
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743
Issue 1
November 2000
Installing the System
35Connecting the Hospitality Adjuncts
Co-Resident INTUITY Lodging Call Accounting
Link Using the DCE Port
This connection is used to transfer Call Detail Recording (CDR) information to the
co-resident INTUITY Lodging Call Accounting software (Homisco). This
connection is valid for a
csi
or
si
system.
Parts List
The DCE port on the switch (this port is found on the Processor Interface
Cable of a
csi
system labeled as J2)
One M25A RS232 cable (or equivalent straight-through cable)
(comcode 105193668)
One Equinox P/N:210068 DTE 10/10 adapter (DB25 DTE,
comcode 406983155); see “Appendix B — Connector Pinouts”
One D6AP modular cord (comcode 102937604)
One Multi-Port Serial card on the MAP (comcode 407009406; J1P260AA1,
List 12).
For this connection, use the first port on the card. This port is not marked
on the card, but is administered in software as port TTYsaa.
Distance Limits
The distance limit from the switch to the MAP is 50 feet (15.2 meters). If the
distance from the switch and the MAP is more than 50 feet (15.2 meters), or if the
switch is an
r
system, see “Switch-to-Call Accounting Link using DCP Data
Modules” on page 46.