Avaya 555-231-743 Life Jacket User Manual


 
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743
Issue 1
November 2000
Translations and Testing
180Switch-to-INTUITY Translations
status link
X
, where
X
is the X.25 link number.
The following tests can be run from the INTUITY to test the link to the switch:
Use the command Lodging Administration, press to bring up the
command menu, and select LDG/PMS Link Restart to restart the switch-
to-INTUITY link.
Customer/Services Administration > Diagnostics > Switch Link
Diagnostics > Link Diagnostics
This screen is an example of an X.25 link. It shows the link being in service
and the link level as up.
After pressing to change the function key labels, the following function
keys control the status of the link:
busies-out the link
releases the link from busy-out
performs diagnostics on the link.
Continue with “INTUITY AUDIX Voice Ports (Switch)” on page 183.
status link 1 Page 1 of 3
LINK/PORT STATUS
Link Number: 1
Link Status: connected
Link Type: x.25
Link Name: intuity link
Service Port Location: 01C0301
Service Port Data Extension: 2005
Service Stats: in-service/active
Enabled? y
Maintenance Busy? n
Active Channels: 0
CONNECTED TO:
Destination: TDMODULE Destination Port: 1C0303
Destination Status: in-service/active Destination Extension: external
AC: 1 Connected/Orig
F7
+------------------------------------------------------------------------------+
+ Diagnose Switch Link +
+------------------------------------------------------------------------------+
| STATUS SWITCH-LINK |
| |
| Type Baud State |
| DCIU 9600 In Service |
| |
| Link Level 2 is Up |
| |
| DCIU switches (In/Out of data transfer) |
| 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 |
| I |
+------------------------------------------------------------------------------+
F8
F2
F3
F4