Avaya 555-231-743 Life Jacket User Manual


 
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743
Issue 1
November 2000
Installing the System
13Setting Up the Initial Options
2. Before you do any administration, verify that you are using the correct
translation card. For a DEFINITY ECS or ProLogix system, you will start
with a blank card, and all options must be set on site. For GuestWorks and
DEFINITY BCS, there is a default translation card that is already
administered for Offer Category B with certain default options. Check this
by using the display system-parameters offer-options command.
NOTE:
If the Offer Category is not set correctly and activated, contact
the technical support group or your regional Center of
Excellence (COE). The switch must be set to the correct Offer
Category; the translations must be saved; and the switch must
be reset before you can do any translations.
3. Set the required country options using the change system-parameters
country-options command.
4. Set the daylight savings time rules using the change daylight-savings-
rules command.
5. Set the date and the time using the set time command. This includes
applying the daylight savings time rules set up in Step 4.
6. If the switch has EPNs in different time zone locations, use the change
location command to set the time zone offset, daylight savings rules, and
numbering plan area code.
7. Set the switch maintenance parameters using the change system-
parameters maintenance command. For
csi
systems that have a C-LAN
(TN799C) circuit pack, use Page 2 of this screen to verify that the Bus
Bridge Packet Interface 2 has been enabled for the C-LAN circuit pack. If it
is not already assigned, enter the C-LAN circuit pack equipment location,
and use the defaults for the Timeslot Port fields as shown below.
change system-parameter maintenance Page 2 of 4
MAINTENANCE-RELATED SYSTEM PARAMETERS
MINIMUM MAINTENANCE THRESHOLDS ( Before Notification )
TTRs: 4 CPTRs: 1 Call Classifier Ports:
MMIs: 0 VCs:
TERMINATING TRUNK TRANSMISSION TEST (Extension)
Test Type 100: Test Type 102: Test Type 105:
ISDN MAINTENANCE
ISDN-PRI TEST CALL Extension: ISDN BRI Service SPID:
DS1 MAINTENANCE
DSO Loop-Around Test Call Extension:
SPE OPTIONAL BOARDS
Packet Intf1? y Packet Intf2? y
Bus Bridge: 03C05 Inter-Board Link Timeslots Pt0: 6 Pt1: 1 Pt2: 1