Installing the System
39Connecting the Hospitality Adjuncts
Xiox Call Accounting System Link Using
the DCE Port
This connection is used to transfer CDR information to the Xiox call accounting
system. This connection is valid for a
csi
or
si
system.
Parts List
The DCE port on the switch (this port is found on the Processor Interface
Cable of a
csi
system labeled as J2)
One M25A or M25B cable plus gender changers as needed (or
equivalent 25-pin straight-through cable) to connect from the DCE port to
the PBX port on the Xiox Intelligent Buffer unit
Xiox Intelligent Buffer unit (includes AC power adapter and cable for
connection to the Xiox call accounting PC)
Xiox call accounting PC.
Distance Limits
The distance limit from the switch to the Xiox call accounting PC is 50 feet (15.2
meters). If the distance from the switch and the PC is more than 50 feet (15.2
meters), or if the switch is an
r
system, see “Switch-to-Call Accounting Link using
DCP Data Modules” on page 46.