AT&T 555-230-894 Marine Radio User Manual


 
Test Duplicated Switch Processing Element (SPE)
Interchange
Issue 1 September 1995
8-13
Screen 8-12. Example System Status Report for All Cabinets
4. Note the MODE of SPE 1A and 1B.
5. Type refresh spe and press
ENTER.
Command successfully completed should be displayed.
6. Type reset system interchange and press
ENTER.
This causes the terminal to log off.
7. Log in as craft again. See Chapter 7, "Activate the System" for more
information. Remember to use the new password established for craft.
8. Type status system cabinets-all and press
ENTER.
9. A screen similar to the following should be displayed:
status system all-cabinets SPE A
SYSTEM STATUS CABINET 1
SELECT SPE ALARMS TONE/ SERVICE SYSTEM SYSTEM
SPE MODE SWITCH MAJOR MINOR CLOCK STATE CLOCK TONE
1A active auto 1 0 1A in standby standby
1B maint/init auto 1 0 1B in active active
SERVICE CONTROL DEDICATED SERVICE BUS ALARMS BUS OPEN BUS
TDM STATE CHANNEL TONES PKT STATE MAJOR MINOR FAULTS LEADS
1A in y n 1
1B in n y
EMERGENCY SELECT SERVICE CABINET
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A auto-on 01A01-02A01 in standby MCC
1B auto-on 01B01-02B02 in active
-
-
Command successfully completed
Command: