AT&T 555-230-894 Marine Radio User Manual


 
Test Telephones and Other Equipment
10-14 Issue 1 September 1995
Procedure
1. At control carrier, set Emergency Transfer switch(es) to ON position. See
Note.
NOTE:
Pull out on Switches to overcome detents.
2. At emergency transfer telephone connected to the port network being
tested, pick up the receiver and press Ground Start key, if so equipped.
Dial tone is heard.
3. Dial number associated with an outside number. Audible ringing or busy
tone is heard.
4. Hang up the test telephone.
5. At control carrier, set Emergency Transfer switch(es) to AUTO position.
Test Remote Access Interface (known
as Initialization and Administration
System)
Description
Test the communication link between the switch and Initialization and
Administration System (INADS) and verify the alarm notification process. Make a
remote test from Initialization and Administration System (INADS) to the system
and a local test from the system to Initialization and Administration System
(INADS).
NOTE:
In some countries, this remote access interface is not allowed. Check with
your AT&T representative.
ProcedureRemote Test
1. Call outside personnel who will be accessing the switch remotely to
perform administration, maintenance, and testing.
2. Ask remote access personnel to call system and login and display System
Parameters Maintenance screen. The login must be successful.
NOTE:
Requirement: Product Identification on the System Parameters
screen must match the Product Identification administered by the
local technician.