AT&T 555-230-894 Marine Radio User Manual


 
Option Switch Settings
H-36 September 1995 Issue 1
Refer to "Interface Cabling to Station Message Detail Recording (SMDR) Output
Device" on page 9-63 for connection information.
The 475 or 572 printers can be used as an output receiving device for station
message detail recording (SMDR). The recommended option settings for these
printers are shown in the following tables. Also, a TELESEER, station message
detail recording (SMDR), 94A Local Storage Unit (LSU), or Customer Premises
Equipment (CPE) can be used as the output receiving device. Administration
procedures for station message detail recording (SMDR) (MPDM) equipment are
provided in
DEFINITY Communications System Generic 3 Implementation
,
555-230-653.
Table H-24. Option Switch Settings on Modular Processor
Data Module (MPDM) or Modular Trunk Data
Module (MTDM) for Station Message Detail
Recording (SMDR)
Switch Setting
SELF TEST OFF
LOC LOOP/REM LOOP OFF
1200 BAUD ON
AANS (modular
processor data module
Only)
ON
SIGLS ON
PR TY ON
I/OD ON
All Others OFF
Table H-25. Option Switch Settings on 212-Type Modem
for Station Message Detail Recording (SMDR)
Switch Setting
AL OFF
ST OFF
RDL OFF
DL OFF
HS ON