Issue 1 September 1995 9-1
9
Install and Wire Telephones and
Other Equipment
The wiring procedures are the same for most of the DEFINITY System Generic 3
telephones and other equipment.
This section provides wiring examples. These are examples only and wiring
procedures may differ at each site. This section provides the following examples:
■ 302B Attendant Console with Adjunct Power
■ Analog Station
■ Analog Tie Trunk
■ Digital Tie Trunk
These examples use port circuit board positions relating to those shown in
Chapter 8, "Test the System", Figure 8-4 and Figure 8-5.
Steps 1-3 of each of the following examples should have been completed in the
Provisioning Plan in Chapter 2, "Plan and Prepare the Site".
Telephone Connection Example
The 302B Attendant Console is used in this section to describe a typical
telephone connection. This connection information is typical of the 603E, 84xx
(4-wire), 94xx telephones. Refer to Appendix E for more information on wiring
telephone connections.
The 302B Attendant Console always requires auxiliary power (-48VDC). Power is
connected to the console through Pins 7 and 8 of the information outlet shown in
Figure 9-3. Only three consoles can be powered by the cabinet through the