Mitsubishi Electronics FR-F700-NA Marine Battery User Manual


 
314
Useful functions
Acceleration/deceleration time increment (Pr. 999 ="30(0.1s) or 31(0.01s)")
* The set value is changed for Pr. 21.
Parameter Name
Initial set
increment
Pr.999 = "30"
Pr.999 = "31"
Automatic parameter
setting
Refer to
page
7 Acceleration time 0.1s 0.1s 0.01s 101
8 Deceleration time 0.1s 0.1s 0.01s 101
16
Jog acceleration/deceleration
time
0.1s 0.1s 0.01s 95
21
Acceleration/deceleration time
increments
10
* 1 * 101
44
Second acceleration/
deceleration time
0.1s 0.1s 0.01s 101
45 Second deceleration time 0.1s 0.1s 0.01s 101
264
Power-failure deceleration time
1
0.1s 0.1s 0.01s 156
265
Power-failure deceleration time
2
0.1s 0.1s 0.01s 156
582
Auxiliary motor connection-time
deceleration time
0.1s 0.1s 0.01s 283
583
Auxiliary motor disconnection-
time acceleration time
0.1s 0.1s 0.01s 283
REMARKS
When a parameter is set as the acceleration/deceleration time (0.1s), the 0.01s increment is dropped.
When a parameter is set as the acceleration/deceleration time (0.01s), the parameters are limited at the maximum value of the
parameter setting range. For example, Pr. 7 = "361.0s" when 0.1s increment is selected, and Pr. 7 = "360.00s" when 0.01s
increment is selected.