Parameter List
Parameter list
4
PARAMETERS
RS-485 communication
331
RS-485 communication station
number
0 to 31
(0 to 127, 0 to 247)
10214
332
RS-485 communication speed
3, 6, 12, 24, 48, 96, 192,
384
(96, 192, 384, 768)
196214
333
RS-485 communication stop bit
length
0, 1, 10, 11 1 1 214
334
RS-485 communication parity check
selection
0, 1, 2 1 2 214
335
RS-485 communication retry count 0 to 10, 9999 1 1 214
336
RS-485 communication check time
interval
0 to 999.8s, 9999 0.1s 0s 214
337
RS-485 communication waiting time
setting
0 to 150ms, 9999 1 9999 214
338
Communication operation command
source
0, 1 1 0 204
339
Communication speed command
source
0, 1, 2 1 0 204
340
Communication startup mode
selection
0, 1, 2, 10, 12 1 0 203
341
RS-485 communication CR/LF
selection
0, 1, 2 1 1 214
342
Communication EEPROM write
selection
0, 1 1 0 216
343
Communication error count 10232
390
% setting reference frequency 1 to 400Hz 0.01Hz 60Hz 247
PLC function
414
PLC function operation selection 0, 1 1 0 260
415
Inverter operation lock mode setting 0, 1 1 0 260
Remote
output
495
Remote output selection 0, 1, 10, 11 1 0 137
496
Remote output data 1 0 to 4095 1 0 137
497
Remote output data 2 0 to 4095 1 0 137
498
PLC function flash memory clear 0 to 9999 1 0 260
502
Stop mode selection at
communication error
0 to 3 1 0 216
Maintenance
503
Maintenance timer 0 (1 to 9998) 1 0 304
504
Maintenance timer alarm output set
time
0 to 9998, 9999 1 9999 304
505
Speed setting reference 1 to 120Hz 0.01Hz 60Hz 139
PLC function
506
to
515
Parameter 1 to 10 for user 0 to 65535 1 0 260
522
Output stop frequency 0 to 400Hz, 9999 0.01Hz 9999 120
539
Modbus-RTU communication check
time interval
0 to 999.8s, 9999 0.1s 9999 232
Function Parameters
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting