Parameter List
Parameter list
4
PARAMETERS
125
Terminal 2 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 177
126
Terminal 4 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 177
PID control
127
PID control automatic switchover
frequency
0 to 400Hz, 9999 0.01Hz 9999 261
128
PID action selection
10, 11, 20, 21, 50, 51,
60, 61, 70, 71, 80, 81,
90, 91, 100, 101, 110,
111, 120, 121
110261
129
PID proportional band 0.1 to 1000%, 9999 0.1% 100% 261
130
PID integral time 0.1 to 3600s, 9999 0.1s 1s 261
131
PID upper limit 0 to 100%, 9999 0.1% 9999 261
132
PID lower limit 0 to 100%, 9999 0.1% 9999 261
133
PID action set point 0 to 100%, 9999 0.01% 9999 261
134
PID differential time 0.01 to 10.00s, 9999 0.01s 9999 261
Bypass
135
Electronic bypass sequence selection 0, 1 1 0 293
136
MC switchover interlock time 0 to 100s 0.1s 1s 293
137
Start waiting time 0 to 100s 0.1s 0.5s 293
138
Bypass selection at a fault 0, 1 1 0 293
139
Automatic switchover frequency from
inverter to bypass operation
0 to 60Hz, 9999 0.01Hz 9999 293
Backlash measures
140
Backlash acceleration stopping
frequency
0 to 400Hz 0.01Hz 1Hz 105
141
Backlash acceleration stopping time 0 to 360s 0.1s 0.5s 105
142
Backlash deceleration stopping
frequency
0 to 400Hz 0.01Hz 1Hz 105
143
Backlash deceleration stopping time 0 to 360s 0.1s 0.5s 105
144
Speed setting switchover
0, 2, 4, 6, 8, 10, 102,
104, 106, 108, 110
14139
PU
145
PU display language selection 0 to 7 1 1 315
147
Acceleration/deceleration time
switching frequency
0 to 400Hz, 9999 0.01Hz 9999 101
148
Stall prevention level at 0V input 0 to 120% 0.1% 110% 81
Current detection
149
Stall prevention level at 10V input 0 to 120% 0.1% 120% 81
150
Output current detection level 0 to 120% 0.1% 110% 135
151
Output current detection signal delay
time
0 to 10s 0.1s 0s 135
152
Zero current detection level 0 to 150% 0.1% 5% 135
153
Zero current detection time 0 to 10s 0.01s 0.5s 135
154
Voltage reduction selection during
stall prevention operation
0, 1 1 1 81
155
RT signal function validity condition
selection
0, 10 1 0 125
156
Stall prevention operation selection 0 to 31, 100, 101 1 0 81
157
OL signal output timer 0 to 25s, 9999 0.1s 0s 81
Function
Parameters
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting