Register Name: TSACR
Register Description: Transmit Sa Bit Control Register
Register Address: DAh
Bit # 7 6 5 4 3 2 1 0
Name SiAF SiNAF RA Sa4 Sa5 Sa6 Sa7 Sa8
Default 0 0 0 0 0 0 0 0
Bit 0/Additional Bit 8 Insertion Control Bit (Sa8).
0 = do not insert data from the TSa8 register into the transmit data stream
1 = insert data from the TSa8 register into the transmit data stream
Bit 1/Additional Bit 7 Insertion Control Bit (Sa7).
0 = do not insert data from the TSa7 register into the transmit data stream
1 = insert data from the TSa7 register into the transmit data stream
Bit 2/Additional Bit 6 Insertion Control Bit (Sa6).
0 = do not insert data from the TSa6 register into the transmit data stream
1 = insert data from the TSa6 register into the transmit data stream
Bit 3/Additional Bit 5 Insertion Control Bit (Sa5).
0 = do not insert data from the TSa5 register into the transmit data stream
1 = insert data from the TSa5 register into the transmit data stream
Bit 4/Additional Bit 4 Insertion Control Bit (Sa4).
0 = do not insert data from the TSa4 register into the transmit data stream
1 = insert data from the TSa4 register into the transmit data stream
Bit 5/Remote Alarm Insertion Control Bit (RA).
0 = do not insert data from the TRA register into the transmit data stream
1 = insert data from the TRA register into the transmit data stream
Bit 6/International Bit in Nonalign Frame Insertion Control Bit (SiNAF).
0 = do not insert data from the TSiNAF register into the transmit data stream
1 = insert data from the TSiNAF register into the transmit data stream
Bit 7/International Bit in Align Frame Insertion Control Bit (SiAF).
0 = do not insert data from the TSiAF register into the transmit data stream
1 = insert data from the TSiAF register into the transmit data stream