26.1.1 Number Of Errors Left Register
The host can read the NOELx registers at any time to determine how many errors are left to be inserted.
Register Name: NOEL1
Register Description: Number Of Errors Left 1
Register Address: EEh
Bit # 7 6 5 4 3 2 1 0
Name C7 C6 C5 C4 C3 C2 C1 C0
Default 0 0 0 0 0 0 0 0
Bits 0 to 7/Number of Errors Left Counter Bits 0 to 7 (C0 to C7). Bit C0 is the LSB of the 10-bit counter.
Register Name: NOEL2
Register Description: Number Of Errors Left 2
Register Address: EFh
Bit # 7 6 5 4 3 2 1 0
Name - - - - - - C9 C8
Default 0 0 0 0 0 0 0 0
Bits 0 to 1/Number of Errors Left Counter Bits 8 to 9 (C8 to C9). Bit C9 is the MSB of the 10-bit counter.