Product Preview DS21Q55
88 of 248 012103
Please contact telecom.support@dalsemi.com or search http://www.maxim-ic.com for updated
information.
15.2.1.1 T1 Mode
In T1 ESF framing mode, there are four signaling bits per channel (A, B, C, and D). TS1–TS12 contain a
full multiframe of signaling data. In T1 D4 framing mode, there are only two signaling bits per channel
(A and B). In T1 D4 framing mode, the framer uses the C and D bit positions as the A and B bit positions
for the next multiframe. In D4 mode, two multiframes of signaling data can be loaded into TS1–TS12.
The framer will load the contents of TS1–TS12 into the outgoing shift register every other D4
multiframe. In D4 mode the host should load new contents into TS1–TS12 on every other multiframe
boundary and no later than 120µs after the boundary.
15.2.1.2 E1 Mode
In E1 mode, TS16 carries the signaling information. This information can be in either CCS (common
channel signaling) or CAS (channel associated signaling) format. The 32 time slots are referenced by two
different channel number schemes in E1. In channel numbering, TS0 through TS31 are labeled channels 1
through 32. In phone-channel numbering, TS1 through TS15 are labeled channel 1 through channel 15,
and TS17 through TS31 are labeled channel 15 through channel 30.
TIME SLOT NUMBERING SCHEMES Table 17-1
TS
0
1 2
3
4
5 6
7
8
9 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Channel
1
2 3
4
5
6 7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Phone
Channel
1 2
3
4
5 6
7
8
9 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30