Lucent Technologies 555-230-220 Life Jacket User Manual


 
ASAI and Release 6 Requirements
B-3 Issue 7 March 1998
The maximum number of active domain-control associations
per station is two for R6vs, R6si, and four for R6r.
For R6vs and R6si, the maximum number of associations that
can control a station on a call is three; two domain-control
associations and one call-control association. For R6r, the
maximum number of associations that can control a station on a
call is five; four domain-control associations and one call-control
association.
Per ACD split domain:
The maximum number of active notifications per split domain is
three for R6vs, R6si, and six for R6r.
The maximum number of domain controllers is one.
Per VDN domain:
The maximum number of active notifications per VDN domain is
three for R6vs, R6si, and six for R6r.
Per call:
The maximum number of adjunct-control associations per call is
one.
Table B-3. ASAI Limits per ACD Split Domain
Capacity R6vs and R6si R6r
Active Notifications per Split Domain 3 6
Domain Controllers per Split Domain 1 1
Table B-4. ASAI Limits per VDN Domain
Capacity R6vs and R6si R6r
Active Notifications per VDN Domain 3 6
Table B-5. ASAI Limits per Call
Capacity R6vs and R6si R6r
Adjunct-Control Associations per Call 1 1
Active Notif. Associations per Call 3 6
Domain Control Associations 12 24