Lucent Technologies 555-230-220 Life Jacket User Manual


 
Event Reporting and U-Abort Capabilities
3-10 Issue 7 May 1998
Alerting Event Report Items
The following is a list of items provided with this report:
calling party number
For outgoing calls over PRI facilities — “calling number” from the ISDN
SETUP message
For outgoing calls over non-PRI facilities or on-ECS calls — locally
originating extension
For incoming call over PRI facilities — “calling number” from the ISDN
SETUP message
2
For incoming calls over non-PRI facilities, the calling party number is
generally
not
provided. In this case, the Trunk Group number is provided
instead
For calls originated at a bridged call appearance — the principal’s
extension
For incoming DCS calls, if the DCS calling party information is available to
ECS (if a station with a display gets it), this information is also made
available to ASAI
For incoming calls over R2-MFC facilities, if the calling party information is
provided, it is collected and passed onto the adjunct
trunk group number/trunk group member number
The Trunk Group number and Trunk Group Member number are only provided if
the Calling Party number is unavailable.
called party number (DNIS)
For outgoing calls over PRI facilities, the called number is the one provided
in the SETUP message.
For outgoing calls over non-PRI facilities, the called number is the default
trunk value (#####).
For incoming calls over PRI facilities, the called number is the one provided
in the SETUP message.
For incoming calls over PRI facilities to a VDN that does lookahead
interflow on calls, if the lookahead interflow attempt fails, the called number
provided is the principal extension of the dialed number (instead of the
originally called number). If the interflow attempt is successful, the Called
Party number is provided as the default.
2. See ‘‘Event Reports’’ Section in Chapter 12, ‘‘ASAI and Feature Interactions.’’