Selection of operation mode and operation location
4
PARAMETERS
(2) Select the command source of the PU operation mode (Pr. 551)
Any of the PU connector, RS-485 terminals, or USB connector can be specified as the command source in the PU
operation mode.
Set Pr.551="1" to use the RS-485 terminals to write parameters or send start and frequency commands in the PU
operation mode. Set Pr.551="3 or 9999" to use the USB connector to do those in the PU operation mode.
*1 The Modbus-RTU protocol cannot be used in the PU operation mode. When using the Modbus-RTU protocol, set Pr. 551 to "2".
*2 When the communication option is not fitted, the operation mode cannot be switched to Network operation mode.
*3 When Pr. 551 = "9999", the priorities of the PU command source is USB connector > PU connector.
CAUTION
The PU operation mode has a higher priority when Pr. 550 = "1" (NET mode RS-485 terminals) and Pr. 551 = "1" (PU mode RS-485
terminals). When the communication option is not fitted, therefore, the operation mode cannot be switched to Network operation
mode.
Changed setting value is valid when powering ON or resetting the inverter.
Pr. 550
Setting
Pr. 551
Setting
Command Source
Remarks
PU connector USB connector RS-485 terminals
Communication option
0
1 ××
PU operation mode
*1
NET operation mode *2
2 PU operation mode ××NET operation mode *2
3 × PU operation mode × NET operation mode *2
9999
(initial
value)
PU operation mode
*3
PU operation mode
*3
× NET operation mode *2
1
1 ××
PU operation mode
*1
×
Switching to NET
operation mode disabled
2 PU operation mode × NET operation mode ×
3 ×
PU operation mode
NET operation mode ×
9999
(initial
value)
PU operation mode
*3
PU operation mode
*3
NET operation mode ×
9999
(initial
value)
1 ××PU operation mode
*1 NET operation mode *2
2 PU operation mode ×
× NET operation mode
*2
Communication option
fitted
NET operation mode ×
Communication option
not fitted
3 ×
PU operation mode
× NET operation mode *2
Communication option
fitted
NET operation mode ×
Communication option
not fitted
9999
(initial
value)
PU operation mode
*3
PU operation mode
*3
× NET operation mode *2
Communication option
fitted
NET operation mode ×
Communication option
not fitted