Mitsubishi Electronics FR-A720-0.4k to 90k Marine Battery User Manual


 
357
Communication operation and setting
4
PARAMETERS
Parameter
Parameters
Register Parameter Name Read/Write Remarks
0 to 999
41000 to
41999
Refer to the parameter list (page 71) for
the parameter names.
Read/write
The parameter number + 41000 is the
register number.
C2(902) 41902
Terminal 2 frequency setting bias
(frequency)
Read/write
C3(902)
42092
Terminal 2 frequency setting bias
(analog value)
Read/write
The analog value (%) set to C3 (902) is
read.
43902
Terminal 2 frequency setting bias
(terminal analog value)
Read
The analog value (%) of the voltage
(current) applied to the terminal 2 is read.
125(903) 41903
Terminal 2 frequency setting gain
(frequency)
Read/write
C4(903)
42093
Terminal 2 frequency setting gain
(analog value)
Read/write
The analog value (%) set to C4 (903) is
read.
43903
Terminal 2 frequency setting gain
(terminal analog value)
Read
The analog value (%) of the voltage
(current) applied to the terminal 2 is read.
C5(904) 41904
Terminal 4 frequency setting bias
(frequency)
Read/write
C6(904)
42094
Terminal 4 frequency setting bias
(analog value)
Read/write
The analog value (%) set to C6 (904) is
read.
43904
Terminal 4 frequency setting bias
(terminal analog value)
Read
The analog value (%) of the current
(voltage) applied to the terminal 4 is read.
126(905) 41905
Terminal 4 frequency setting gain
(frequency)
Read/write
C7(905)
42095
Terminal 4 frequency setting gain
(analog value)
Read/write
The analog value (%) set to C7 (905) is
read.
43905
Terminal 4 frequency setting gain
(terminal analog value)
Read
The analog value (%) of the current
(voltage) applied to the terminal 4 is read.
C12(917) 41917 Terminal 1 bias frequency (speed) Read/write
C13(917)
42107
Terminal 1 bias (speed) Read/write Analog value (%) set in C13 (917) is read.
43917
Terminal 1 bias (speed)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C14(918) 41918
Terminal 1 gain frequency (speed) Read/write
C15(918)
42108
Terminal 1 gain (speed) Read/write Analog value (%) set in C15 (918) is read.
43918
Terminal 1 gain (speed)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C16(919) 41919
Terminal 1 bias command (torque/
magnetic flux)
Read/write
C17(919)
42109
Terminal 1 bias (torque/magnetic flux) Read/write Analog value (%) set in C17 (919) is read.
43919
Terminal 1 bias (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C18(920) 41920
Terminal 1 gain command (torque/
magnetic flux)
Read/write
C19(920)
42110 Terminal 1 gain (torque/magnetic flux) Read/write Analog value (%) set in C19 (920) is read.
43920
Terminal 1 gain (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C38(932) 41932
Terminal 4 bias command (torque/
magnetic flux)
Read/write
C39(932)
42122
Terminal 4 bias (torque/magnetic flux) Read/write Analog value (%) set in C39 (932) is read.
43932
Terminal 4 bias (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the current (voltage)
applied to terminal 4 is read.
C40(933) 41933
Terminal 4 gain command (torque/
magnetic flux)
Read/write
C41(933)
42123
Terminal 4 gain (torque/magnetic flux) Read/write Analog value (%) set in C41 (933) is read.
43933
Terminal 4 gain (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the current (voltage)
applied to terminal 4 is read.