Mitsubishi Electronics FR-A720-0.4k to 90k Marine Battery User Manual


 
77
Parameter List
Parameter List
4
PARAMETERS
Power failure stop
261 Power failure stop selection 0, 1, 2, 11, 12 1 0 270
262
Subtracted frequency at deceleration
start
0 to 20Hz
0.01Hz 3Hz 270
263
Subtraction starting frequency 0 to 120Hz, 9999
0.01Hz 60Hz 270
264
Power-failure deceleration time 1 0 to 3600/360s
0.1/0.01s 5s 270
265
Power-failure deceleration time 2
0 to 3600/360s,
9999
0.1/0.01s 9999 270
266
Power failure deceleration time
switchover frequency
0 to 400Hz 0.01Hz 60Hz 270
267
Terminal 4 input selection 0, 1, 2
1 0 286
268
Monitor decimal digits selection 0,1, 9999
1 9999 253
269
Parameter for manufacturer setting. Do not set.
270
Stop-on contact/load torque high-
speed frequency control selection
0, 1, 2, 3, 11, 13 1 0
214,
374
Load torque
high speed frequency control
271
High-speed setting maximum current 0 to 220%
0.1% 50% 374
272
Middle-speed setting minimum current 0 to 220%
0.1% 100% 374
273 Current averaging range 0 to 400Hz, 9999 0.01Hz 9999 374
274 Current averaging filter time constant 1 to 4000 1 16 374
Stop-on contact
control
275
Stop-on contact excitation current low-
speed multiplying factor
0 to 1000%, 9999
0.1% 9999 214
276
PWM carrier frequency at stop-on
contact
0 to 9, 9999/
0 to 4, 9999
*2
1 9999 214
Brake sequence function
278
Brake opening frequency 0 to 30Hz
0.01Hz 3Hz 217
279
Brake opening current 0 to 220%
0.1% 130% 217
280
Brake opening current detection time 0 to 2s
0.1s 0.3s 217
281
Brake operation time at start 0 to 5s
0.1s 0.3s 217
282
Brake operation frequency 0 to 30Hz
0.01Hz 6Hz 217
283 Brake operation time at stop 0 to 5s 0.1s 0.3s 217
284
Deceleration detection function
selection
0, 1
1 0 217
285
Overspeed detection frequency
(Excessive speed deviation detection frequency)
0 to 30Hz, 9999 0.01Hz 9999
117,
217
Droop control
286
Droop gain 0 to 100%
0.1% 0% 376
287
Droop filter time constant 0 to 1s
0.01s 0.3s 376
288
Droop function activation selection 0, 1, 2, 10, 11
1 0 376
291
Pulse train I/O selection 0, 1, 10, 11, 20, 21, 100
1 0
259,
378
292
Automatic acceleration/deceleration 0, 1, 3, 5 to 8, 11
1 0
163,
180,
217
293
Acceleration/deceleration separate
selection
0 to 2
1 0 180
294 UV avoidance voltage gain 0 to 200% 0.1% 100% 270
Password
function
296
Password lock level
0 to 6, 99, 100 to 106,
199, 9999
1 9999 310
297
Password lock/unlock
(0 to 5), 1000 to 9998,
9999
1 9999 310
299
Rotation direction detection selection
at restarting
0, 1, 9999 1 0 266
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting