Mitsubishi Electronics FR-A720-0.4k to 90k Marine Battery User Manual


 
76
Parameter List
Parameter List
Output terminal function assignment
190
RUN terminal function selection
0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 55,
64, 70, 83 to 85, 90 to 99,
100 to 108, 110 to 116,
120, 125 to 128,
130 to 136, 139,
141 to 147, 155, 164,
170, 183 to 185,
190 to 199, 9999
1 0 239
191
SU terminal function selection 1 1 239
192
IPF terminal function selection
1 2 239
193
OL terminal function selection
1 3 239
194
FU terminal function selection
1 4 239
195
ABC1 terminal function selection
0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 55,
64, 70, 83 to 85, 90, 91,
94 to 99, 100 to 108,
110 to 116, 120,
125 to 128, 130 to 136,
139, 141 to 147, 155,
164, 170, 183 to 185,
190, 191, 194 to 199,
9999
1 99 239
196
ABC2 terminal function selection 1 9999 239
Multi-speed
setting
232 to 239
Multi-speed setting(8 speed to 15
speed)
0 to 400Hz, 9999
0.01Hz 9999 165
240 Soft-PWM operation selection 0, 1 1 1 284
241
Analog input display unit switchover 0, 1
1 0 294
242
Terminal 1 added compensation
amount (terminal 2)
0 to 100%
0.1% 100% 290
243
Terminal 1 added compensation
amount (terminal 4)
0 to 100%
0.1% 75% 290
244
Cooling fan operation selection 0, 1
1 1 385
Slip compensation
245
Rated slip 0 to 50%, 9999
0.01% 9999 151
246 Slip compensation time constant 0.01 to 10s 0.01s 0.5s 151
247
Constant-power range slip
compensation selection
0, 9999
1 9999 151
250
Stop selection
0 to 100s,1000 to 1100s,
8888, 9999
0.1s 9999 213
251
Output phase failure protection
selection
0, 1
1 1 276
Frequency compensation
function
252
Override bias 0 to 200%
0.1% 50% 290
253
Override gain 0 to 200%
0.1% 150% 290
Life check
255
Life alarm status display (0 to 15)
1 0 386
256
Inrush current limit circuit life display (0 to 100%)
1% 100% 386
257
Control circuit capacitor life display (0 to 100%)
1% 100% 386
258
Main circuit capacitor life display (0 to 100%)
1% 100% 386
259
Main circuit capacitor life measuring 0, 1
1 0 386
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting