Mitsubishi Electronics FR-A720-0.4k to 90k Marine Battery User Manual


 
68
Operation panel (FR-DU07)
4.1 Operation panel (FR-DU07)
4.1.1 Parts of the operation panel (FR-DU07)
Setting dial
(Setting dial: Mitsubishi inverter
dial)
Used to change the
frequency setting and
parameter settings.
Operation mode switchover
Used to switch between the PU and External operation mode.
When using the External operation mode (operation using a separately
connected frequency setting potentiometer and start signal), press this key to
light up the EXT indicator. (Change the Pr.79 value to use the combined mode.)
PU: PU operation mode
EXT: External operation mode
Monitor (4-digit LED)
Shows the frequency, parameter
number, etc.
Monitor indicator
Lit to indicate monitoring mode.
PU: Lit to indicate PU operation mode.
EXT: Lit to indicate External operation mode.
NET: Lit to indicate Network operation mode.
Rotation direction indicator
REV: Lit when reverse rotation
FWD: Lit when forward rotation
Start command
forward rotation
Start command
reverse rotation
Stop operation
Used to stop Run
command.
Fault can be reset when
protective function is
activated (fault).
Mode
switchover
Used to change
each setting mode.
Unit indicator
· Hz: Lit to indicate frequency.
· A: Lit to indicate current.
· V: Lit to indicate voltage.
(Flicker when the set frequency monitor is
displayed.)
* Energy saving monitor is displayed when the
energy saving monitor of Pr. 52 is set.
Used to set each setting.
If pressed during operation, monitor
changes as below.
Running
frequency
Output
current
Output
voltage
Operation mode indicator
On: Forward/reverse operation
Flickering: When the frequency command is
not given even if the
forward/reverse command is given.
When the MRS signal is input.
*
No function