Mitsubishi Electronics FR-A720-0.4k to 90k Marine Battery User Manual


 
84
Parameter List
Parameter List
Calibration parameters
C12
(917)
*7
Terminal 1 bias frequency (speed) 0 to 400Hz 0.01Hz 0Hz 294
C13
(917)
*7
Terminal 1 bias (speed) 0 to 300% 0.1% 0% 294
C14
(918)
*7
Terminal 1 gain frequency (speed) 0 to 400Hz
0.01Hz 60Hz 294
C15
(918)
*7
Terminal 1 gain (speed) 0 to 300%
0.1% 100% 294
C16
(919)
*7
Terminal 1 bias command (torque/
magnetic flux)
0 to 400%
0.1% 0% 300
C17
(919)
*7
Terminal 1 bias (torque/magnetic flux) 0 to 300%
0.1% 0% 300
C18
(920)
*7
Terminal 1 gain command (torque/
magnetic flux)
0 to 400% 0.1% 150% 300
C19
(920)
*7
Terminal 1 gain (torque/magnetic flux) 0 to 300%
0.1% 100% 300
C38
(932)
*7
Terminal 4 bias command (torque/
magnetic flux)
0 to 400%
0.1% 0% 300
C39
(932)
*7
Terminal 4 bias (torque/magnetic flux) 0 to 300%
0.1% 20% 300
C40
(933)
*7
Terminal 4 gain command (torque/
magnetic flux)
0 to 400%
0.1% 150% 300
C41
(933)
*7
Terminal 4 gain (torque/magnetic flux) 0 to 300% 0.1% 100% 300
989 Parameter copy alarm release 10/100 1 10/100 *2 397
PU
990 PU buzzer control 0, 1 1 1 395
991
PU contrast adjustment 0 to 63
1 58 395
Clear
parameters
Pr. CL
Parameter clear 0, 1
1 0 396
ALLC All parameter clear 0, 1 1 0 396
Er.CL Faults history clear 0, 1 1 0 399
PCPY
Parameter copy 0, 1, 2, 3
1 0 397
*1 Differ according to capacities.
6%: 0.4K, 0.75K
4%: 1.5K to 3.7K
3%: 5.5K, 7.5K
2%: 11K to 55K
1%: 75K or higher
*2 Differ according to capacities.
(55K or lower/75K or higher)
*3 Differ according to capacities.
5s: 7.5K or lower
15s: 11K or higher
*4 Differ according to capacities.
4%: 7.5K or lower
2%: 11K to 55K
1%: 75K or higher
*5 Differs according to the voltage class. (200V class/400V class)
*6 Setting can be made only when the FR-A7AP/FR-A7AL is mounted.
*7 The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting