Mitsubishi Electronics FR-A720-0.4k to 90k Marine Battery User Manual


 
1/1 BCN-C22005-642
FR-V500, A700, A701 Series
Instruction Manual Supplement
When installing a thermal relay to the cooling fan of the vector-control dedicated motors (SF-
V5RU), use the following recommended thermal relay settings.
200V class (Mitsubishi dedicated motor [SF-V5RU (1500r/min series)])
400V class (Mitsubishi dedicated motor [SF-V5RUH (1500r/min series)])
*1 Power (current) at 50Hz/60Hz.
*2 The cooling fan is equipped with a thermal protector. The cooling fan stops when the coil temperature exceeds
the specified value in order to protect the fan motor. A restrained cooling fan or degraded fan motor insulation
may causes the rise in coil temperature. The fan motor re-starts when the coil temperature drops to normal.
*3 The voltage and input values are the standard specifications of the cooling fan in free air. When the cooling fan
is used with a motor, it requires more energy to perform its work, and thus the above input values become
slightly larger. The cooling fan can, however, be used as it is without causing problems. When a thermal relay is
to be prepared at the customer's side, use the recommended thermal relay settings.
Motor type
SF-V5RU
K
1 2 3 5 7 11 15 18 22 30 37 45 55
Cooling fan (with
thermal protector)*2*3
Voltage
Single-phase 200V/50Hz
Single-phase 200V to 230V/60Hz
Three-phase 200V/50Hz
Three-phase 200 to 230V/60Hz
Input *1
36/55W
(0.26/0.32A)
22/28W
(0.11/0.13A)
55/71W
(0.37/0.39A)
100/156W
(0.47/0.53A)
85/130W
(0.46/0.52A)
Thermal relay
settings
0.36A 0.18A 0.51A 0.69A 0.68A
Motor type
SF-V5RUH
K
1 2 3 5 7 11 15 18 22 30 37 45 55
Cooling fan (with
thermal protector)*2*3
Voltage
Single-phase 200V/50Hz
Single-phase 200V to 230V/60Hz
Three-phase 380 to 400V/50Hz
Three-phase 400 to 460V/60Hz
Input *1
36/55W
(0.26/0.32A)
22/28W
(0.11/0.13A)
55/71W
(0.19/0.19A)
100/156W
(0.27/0.30A)
85/130W
(0.23/0.26A)
Thermal relay
settings
0.36A 0.18A 0.25A 0.39A 0.34A
bcnc22005642.fm 1 ページ 2013年1月21日 月曜日 午後3時17分