Mitsubishi Electronics FR-A720-0.4k to 90k Marine Battery User Manual


 
73
Parameter List
Parameter List
4
PARAMETERS
Motor constants
80
Motor capacity
0.4 to 55kW, 9999/
0 to 3600kW, 9999
*2
0.01/0.1kW *2 9999
148,
189
81
Number of motor poles
2, 4, 6, 8, 10, 12, 14, 16,
18, 20, 9999
1 9999
148,
189
82
Motor excitation current
0 to 500A, 9999/
0 to 3600A, 9999
*2
0.01/0.1A
*2
9999 189
83 Rated motor voltage 0 to 1000V 0.1V 200/400V *5 189
84 Rated motor frequency 10 to 120Hz 0.01Hz 60Hz 189
89
Speed control gain (Advanced magnetic
flux vector)
0 to 200%, 9999
0.1% 9999 148
90
Motor constant (R1)
0 to 50Ω, 9999/
0 to 400mΩ, 9999
*2
0.001Ω/
0.01mΩ
*2
9999 189
91
Motor constant (R2)
0 to 50Ω, 9999/
0 to 400mΩ, 9999
*2
0.001Ω/
0.01mΩ
*2
9999 189
92
Motor constant (L1)
0 to 50
Ω
(0 to 1000mH), 9999
/
0 to 3600m
Ω
(0 to 400mH), 9999
*2
0.001
Ω
(0.1mH)/
0.01m
Ω
(0.01mH)
*2
9999 189
93 Motor constant (L2)
0 to 50
Ω
(0 to 1000mH), 9999
/
0 to 3600m
Ω
(0 to 400mH), 9999
*2
0.001
Ω
(0.1mH)/
0.01m
Ω
(0.01mH)
*2
9999 189
94
Motor constant (X)
0 to 500
Ω
(0 to 100%), 9999/
0 to 100
Ω
(0 to 100%), 9999
*2
0.01Ω (0.1%)/
0.01Ω (0.01%)
*2
9999 189
95
Online auto tuning selection 0 to 2
1 0 199
96
Auto tuning setting/status 0, 1, 101
1 0 189
Adjustable 5 points V/F
100
V/F1(first frequency) 0 to 400Hz, 9999
0.01Hz 9999 164
101
V/F1(first frequency voltage) 0 to 1,000V
0.1V 0V 164
102 V/F2(second frequency) 0 to 400Hz, 9999 0.01Hz 9999 164
103 V/F2(second frequency voltage) 0 to 1,000V 0.1V 0V 164
104 V/F3(third frequency) 0 to 400Hz, 9999 0.01Hz 9999 164
105
V/F3(third frequency voltage) 0 to 1,000V
0.1V 0V 164
106
V/F4(fourth frequency) 0 to 400Hz, 9999
0.01Hz 9999 164
107
V/F4(fourth frequency voltage) 0 to 1,000V
0.1V 0V 164
108
V/F5(fifth frequency) 0 to 400Hz, 9999
0.01Hz 9999 164
109
V/F5(fifth frequency voltage) 0 to 1,000V
0.1V 0V 164
Third functions
110
Third acceleration/deceleration time 0 to 3600/360s, 9999
0.1/0.01s 9999 172
111 Third deceleration time 0 to 3600/360s, 9999 0.1/0.01s 9999 172
112 Third torque boost 0 to 30%, 9999 0.1% 9999 146
113 Third V/F (base frequency) 0 to 400Hz, 9999 0.01Hz 9999 159
114
Third stall prevention operation current 0 to 220%
0.1% 150% 152
115
Third stall prevention operation
frequency
0 to 400Hz
0.01Hz 0Hz 152
116 Third output frequency detection 0 to 400Hz 0.01Hz 60Hz 246
PU connector
communication
117 PU communication station number 0 to 31 1 0 333
118
PU communication speed 48, 96, 192, 384
1 192 333
119
PU communication stop bit length 0, 1, 10, 11
1 1 333
120
PU communication parity check 0, 1, 2
1 2 333
121
Number of PU communication retries 0 to10, 9999
1 1 333
122
PU communication check time interval 0, 0.1 to 999.8s, 9999
0.1s 9999 333
123
PU communication waiting time setting 0 to 150ms, 9999
1ms 9999 333
124 PU communication CR/LF selection 0, 1, 2 1 1 333
125
Terminal 2 frequency setting gain
frequency
0 to 400Hz
0.01Hz 60Hz 294
126
Terminal 4 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 294
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting