National Instruments 371889A-01 SONAR User Manual


 
Setting Schematic Capture Preferences
Multicap 9 User Guide 3-21
3.4.1.3 Preferences - Parts Tab
The options in this tab determine where you set up component placement mode, the symbol
standard (ANSI or DIN), phase shift direction and digital simulation settings.
1. In the
Place component mode box, select one of:
Place single component Allows you to place one selected component at a time.
Continuous placement for multi-section part only Allows you to place multiple
sections of a multi-section component. For example, 7400N has four NAND gates, so
using this option means each time you place a 7400N you place a different one of its
NAND gates. Refer to 4.4.1 Using the place component browser on page 4-4 for an
example of multi-section part placement.
Continuous placement Allows you to place several components of the same type by
continuing to click on the workspace after each component is placed. End continuous
placement by pressing E
SC.
Optionally, enable the
Return to Component Browser After Placement checkbox to display
the
Select a Component dialog box after you place a component on the workspace. This is
useful when you have many parts to place. (Click E
SC when finished part placement).