Embraer Prodigy
®
Flight Deck 100 Pilot’s Guide
190-00728-04 Rev. A
408
HAZARD AVOIDANCE
Theannunciation‘GSINH’or‘GPINH’isdisplayedonthePFDandTAWS-APagewhenGSDAlertingis
inhibited.DiscretionshouldbeusedwheninhibitingGSDalerts.InhibitingGSDalertshasnoeffectonthe
vertical guidance provided by the flight instruments.
ALTITUDE VOICE CALLOUT (VCO)
TAWS-Aprovidesauralaltitudeadvisoryalertsastheaircraftdescends.VCOalertsarebasedontheheight
aboveterrainwhentheaircraftismorethan5nmfromanairport,ortheheightabovethenearestrunway
thresholdelevationifwithin5nmofanairport.
VCOalertsbeginat500feetwiththeauralmessage“Five Hundred”.Maintenancepersonnelmaycongure
additionalVCOalertstooccurat400,300,200and100feetduringdescent.
Therearenodisplayannunciationsorpop-upalertsthataccompanytheauralVCOalert(s).
SYSTEM STATUS
Duringpower-up,TAWS-Aconductsaself-testofitsauralandvisualannunciations.Thesystemtestcanalso
bemanuallyinitiated.Asinglechimeisissuedattestcompletion.TAWS-ASystemTestingisdisabledwhen
groundspeedexceeds30knots.TAWS-Aterrainalertswillnotbeissuedwhileatestisinprogress.
Alert Type
PFD/MFD TAWS-A
Page Status
Annunciation
Additional
TAWS-A Page
Annunciation
Aural Message
TAWS System Fail
TAWS FAIL
“TAWS System Failure”
GPWS System Fail None “GPWS System Failure”
System Test in progress
TAWS TEST
None
System Test pass None None “TAWS System Test OK”
Table 6-11 TAWS-A System Test Status Annunciations
Manually testing the TAWS-A System:
1) Select the TAWS-A Page.
2) Press the MENU Key.
3) Select ‘Test TAWS System’ and press the ENT Key to confirm the selection. (Figure 6-106)