114 · Vector Chart material
Messages, which contain only notice
If you tried to load charts for which
you do not have permit, you will get
one of the following messages:
Messages, which require careful attention
All messages in this chapter change the legal status of the charts in your system. Study these message extremely
careful because you may need to use paper charts to fulfil SOLAS requirements
You do not have a valid Permit
A Chart was not converted into
SENC because the Permit has
expired.
A Chart was not converted into
SENC because a Permit with
unknown edition was for different
edition.
You can check edition of the Permit
using Permit Management window
and the edition of Chart using Cell
Status window.
Typical reason is that the chart has been updated too many times as new
edition instead of update. Ask for new permits from your chart agent.
A Chart was not converted into
SENC because your Permit was for
different edition.
You can check edition of the Permit
using Permit Management window
and the edition of Chart using Cell
Status window.
Typical reason is that the chart has been updated too many times as new
edition instead of update. Ask for new permits from your chart agent.
A Chart was not converted into
SENC because the software, data and
system time in the ECDIS indicates
tampering.
Typical reason is that RENC released chart before the issue date of the
chart.
Authentication of chart failed
The Chart is not loaded because of
missing Signature.