Furuno fea2100 Marine GPS System User Manual


 
User chart control · 277
How to select an Area of User Chart to be modified
In Area object field Current indicates which Area of User Chart is selected to be modified. If you want another
area to be modified, you have three alternatives to do it:
· Enter desired Area number of User chart object in Record field to Current edit box. To modify number take
cursor to Current edit box and press Select button. Enter desired number and press OK.
· Use First, <<, >>, Last buttons to find appropriate Area of User chart.
· Use INFO/HELP push button to select Area of User chart. Take cursor into the Electronic chart area above
desired Area one of its corner point and press INFO/HELP push button.
How to change position of corner point
The easiest way to move corner point is drag and drop it to desired position. To do it, proceed as follow:
1. Select display of electronic chart area so you can see desired Area of User Chart on display.
2. Take cursor above a corner point you want to move to new position.
3. Press CHART ALING push button and move cursor to desired position. Keep CHART ALIGN button pressed
down while you move cursor and release it when cursor is in right position.
How to delete an Area of User Chart
To delete complete Area of User Chart, select desired Area object to be displayed in Area Object field and press
Delete button.
How to import Areas of User Chart
You can copy Areas of User Chart from another User Chart file to active User Chart file.
1. Create or open existing User chart file. Open Areas sheet.
2. Press Import button in Area Object field.
3. An User Chart Import dialog box appears
Select Chart from which you want to copy Areas
4. Total record count shows number of areas stored in selected User Chart. Enter into First record to copy field
Area number from which you want to start copying.
5. Enter Number of records field how many areas you want copy into active User Chart file.
6. Press Copy button to copy selected areas. If you do not want copy exit this dialog box by pressing CANCEL in
Control Panel.