37xxxE OM A-107
ALPHABETICAL LISTING G
MENU DESCRIPTION GPIB COMMAND
SWEPT POWER
GAIN COMPRESSION
None
SET FREQUENCIES Calls menu GC_DF2, with it extended menu
EXT_GC_DF2. There the you may enter from 1 to 10
discrete frequencies to be used by the application.
None
PSTART
-XX.XX dBm
Defines the power sweep. The start and stop are limited
by the actual power control range of the internal source.
The stepsize resolution is limited to 0.05 dB.
PSTRT; PSTRT?
PSTOP
-XX.XX dBm
PSTOP; PSTOP?
STEPSIZE
X.XX dB
PSTEP; PSTEP?
ATTENUATION Calls menu GC_SU2, which lets you set attenuation values. None
GAIN COMPRESSION
POINT (MAX REF)
XX.XX dB
This option is used with marker search functions. Value
has a range from 0.05 to 9.99 dB and a default value of
1.00 dB. The search value is [negative] the gain
compression point value. The reference is based on
(maximum) with tracking ON.
GCMP
NOMINAL OFFSET
-XX.XX dB
This value is the approximate gain (or loss) of the external
devices preceding the AUT. Specifically, the gain of the
amplifier and attenuator combination. This value is used
whenever power linearity is turned OFF (while still existing)
to prevent an unexpected jump in the power to the AUT.
NOFST; NOFST?
MORE Calls menu GC3, with is companion menu EXT_CG3. None
PRESS <ENTER>
TO SELECT
Pressing the Enter key implements your menu selection. None
Menu GC2, Swept Power Gain Compression 1