APPENDIX A. STRATA CS CONFIGURATION SETTINGS A-3
BETA DOCUMENT - PRELIMINARY & CONFIDENTIAL
HKLM\Software\Toshiba\Strata CS\Server\Setting
s
..\Server\Settings\
AnalogMinTrunkOnhookTime
DWORD value specifying the minimum on-hook time in milliseconds
before the trunk will be used for another outbound call.
Default is 3000 milliseconds.
BCPComPort
DWORD value specifying the COM port used to connect to the BCP
panel for Watchdog mode. The watchdog signal is transmitted by Strata
CS over a serial cable that connects the PC COM port to the “RS-232
Watchdog Signal” port on the connection panel.
Default is 1, indicating that the serial cable is connected to the COM1
port. If you are using the COM1 port for another device, such as a mouse,
change this setting to 2 and use the COM2 port.
ConferenceMgr1 and ConferenceMgr2
In an environment that has both Strata and MSI station boards, these
values specify whether Strata CS uses all of the available conference
managers on the Strata boards before using the conference managers on
the MSI boards, or vice versa.
The following case-sensitive codes are used to refer to the MSI and
Strata boards:
TvMsi.TerminalMgr
and
TvStrata.TerminalMgr
.
Default settings use the conference managers on the MSI boards first:
ConferenceMgr1 =
“TvMsi.TerminalMgr”
,
ConferenceMgr2 =
“TvStrata.TerminalMgr”
DbCacheInterval
DWORD value specifying the number of minutes between database
cache refreshes.
Default is
5
minutes. Setting to zero to turns off cache refreshes.
DisableDevices
See “Disabling Dialogic devices” on page A-13 for details.
Default is
0
.